For over 80 years the parker sporlan division has set the industry standard for the development and manufacture of leading edge high quality hvacr components. Sporlan kit refers to a leaky valve caused by manual lift stem. Several materials are available, including brass, 304 stainless steel, 316 stainless steel, ptfe teflon, and aluminum. Sporlan valve company me14s250hp sporlan solenoid r410 58 price. Liquidline service solenoid valve hvac troubleshooting. The solenoid is an electromagnetic part of a valve, comprised of a coil, core tube, core and enclosure. Replacing internal components on sporlan solenoid valve. Yellow jacket 60617 sporlan valve wrench spanner end tightens packing nut around super heat adjustment stem. It fits all standard sporlan solenoid valves except the types w3, b33, e33, e35, e42, e43, kbr183, kb. Turning the manual lift stem clockwise will lift the main piston off the seat. Valves are shipped without the solenoid coils vlc valve less coil. Place the seat disc into the valve body with the smaller diameter end facing up.
Sporlan solenoid valves of this design are the types a3, e3, ma5a3, 180 solenoid pilot control and w3p1. Ascos 2way solenoid valves have one inlet and one outlet, and are used. This effect is further aggravated by high velocity ammonia mixed with dirt or scale passing through the port of the expansion valve. Class f temperature rating coil types mkc1, mkc2, and omkc2. All sporlan solenoid valves are designed for liquid, suction and discharge gas applications.
Jul 19, 2016 use a sporlan strainer for water applications upstream of every industrial solenoid valve. Adjust the superheat setting on the expansion valve duration. Buy solenoid valve r184p1 less coil 12 inch fnpt 392200. They will require all of the information you can get from the markings on the valve. This document describes the procedure for identifiing the date codes of ma17 series solenoid valves. Process valves for air, water, liquids, and steam stcs high performance line of solenoid process valves offer a wide range of capabilities to suit your unique operating conditions. Parker hydraulic solenoid valves parker direct operated. Tight closing through use of synthetic seating material. Please contact sporlans technical support department for help with your specific valve. We are shipping from just north of boston, ma in the usa. The valve manufacturers instructions give the number of stem turns per degree of superheat. Solenoid direction control valve with manual switch type and solenoid directional control valve with adjustment type the series of manually adjust the solenoid valve. All solenoid valves are tested and rated in accordance with a.
The subject valves had previously been operating at the correct superheat setting. The solenoid pilot control does not directly close the liquid line, but acts on the thermostatic expansion valve causing the expansion valve to close. Bulletin 3010 page 1 sporlan solenoid valves benefits molded coil for most sizes. Yellow jacket 60617 sporlan valve wrench tequipment. Because of possible damage to valve components due to the high temperatures of soldering and brazing, b series solenoid valves with brass.
Troubleshooting solenoid valves in refrigeration applications. Solenoid valves having a type number starting with the letter x are special solenoid valves nonstandard. Fortunately, seat erosion can be minimized and valve. Deduct 218 for e42 series valves less manual lift stem. Do not use this item for any installation or repair of potable water applications. Solenoid valves asco redhat general service, miniature. Then a further onequarter to onehalf turn clockwise will compensate for system variables during operation. Pilot operated normally closed solenoid valves in a pilot operated valve, the stem and plunger assembly opens a pilot port. Liquid line solenoid valve seat leak or interrupted pumpdown liquid refrigerant can continue to feed the tev andor remain in evaporator upon shutdown causing floodback to the compressor upon startup. This is typically normal as it is dissipating heat.
Proceed to adjust the valve by turning the valve stem clockwise to increase superheat until the system is just stable. Order from heritage parts the leading online provider of oem commercial kitchen replacement parts. A solenoid electromagnet with its core a valve body containing one or more orifices flow through an orifice is shut off or allowed by the movement of the core when the solenoid is energized or deenergized. The solenoid valve will become warm or uncomfortably hot to the touch.
Yellow jacket 60617 sporlan valve wrench at the test. Parkers comprehensive selection of solenoid valves includes a broad range of types and configurations for all manner of applications across many industrial markets. We attempt to take photos that show the important features, parts, labels, connections, defects, scuffs, scratches and imperfections of each item. The solenoid coil is 240v mkc2 sporlan and i hear it click when my ranco etc11 thermostat get to my differential set point of 0 degrees, but when my freezer pulls down to 10 degrees the thermostat drops out the solenoid coil but the solenoid valve doesnt close.
Parker valve brand names include apitech, colorflow, commercial, denison, gresen, iqan, manatrol, manapak, schrader bellows, republic, sinclair collins, skinner, sporlan and sterling. Feedback we appreciate your positive feedback square end adjusts sporlan solenoid valves with manual lift stems as on series b6 and e6 through ma 50. Whenever possible, compare the superheat to information provided by the equipment manufacturer. Manual reset valve, latched, energized a solenoid valve is a combination of two basic functional units.
Solenoid direction control valve with manual switch type and solenoid directional control valve with adjustment type the series of manually adjust the solenoid valve hdg02dlbac to inquiry. Evaporator pressure regulating valves sporlan online. The series of manually adjust the solenoid valve power. Locate the word in or the directional arrow on the valve body. Never force the adjustment stem in either direction. The primary purpose of a solenoid valve in a refrigerant liquid line is to prevent flow into the evaporator during the off cycle. Page 4 bulletin 3010 type number connections inches port size inches tons of refrigeration a and b s series valve e series extended connections without manual lift stem with manual em lift st without manual lift stem with manual lift stem 22 4a 401a 402a ssure drop pre psi normally closed.
The 180 is installed in the external equalizer line of the thermostatic expansion valve and has a third 14. We attempt to take photos that show the important features, parts, labels, connections. Risk control bulletin ammonia refrigeration faulty. Sporlan valve f6solenoid 34 npt r246p1 rating select rating 1 star worst 2 stars 3 stars average 4 stars 5 stars best name. The 60617 spanner end tightens packing nut around super heat adjustment stem.
Please contact sporlan s technical support department for help with your specific valve. This product does not comply with the safe drinking water act, which requires that products meet lowlead standards in order to be used in systems providing water for human consumption drinking or cooking. Po boxes apos require usps shipping, may experience longer lead times. Adjust the superheat one or two degrees at a time and give the system ten to fifteen minutes to rebalance. Spanner end tightens packing nut around super heat adjustment stem. Our solenoid valve family of products offers countless benefits, including peerless reliability, compact and. The scope of this document applies to all ma17 series solenoid valves. Catalog 301 page 53 evaporator pressure regulating valves soritpi2, 3, 4 and 5 features n piloted internally no high side connection required n superior corrosion resistance n optional solenoid stop feature to close valve during defrost n optional electric open feature for two temperature operation n manual lift stem standard to allow system evacuation. Count the total number of turns front seat to back seat, then front seat the adjustment stem to 50% of the total turns counted. Process valves, water solenoid valve, steam valve, diaphragm.
The sporlan type a, b and e series solenoid valves are provided as two basic types of solenoid valves. We can supply a superior array of solenoid valve solutions, covering a wide selection of function and material types. An exploded view of a typical solenoid valve is illustrated on page 4 in. Sporlan solenoid repair kit sporlan solenoid valve. Application the basic function of the soritpi valve is to pre. The factory setting of a sporlan tev is close to center stem. In pilot operated valves, dirt, scale or sludge may prevent the piston, disc or diaphragm from closing. Risk control bulletin ammonia refrigeration faulty solenoid. On multiple systems, a solenoid valve may be used in each liquid line leading to the individual evaporators. Sporlan valve company me14s250hp sporlan solenoid r410 58. We do our best to price each item fairly and realistically. Remedy disassemble and clean solenoid valve andor replace damaged internal parts if seat leakage is the problem. Does it have to be adjusted or left backed out until it stops.
Fortunately, seat erosion can be minimized and valve life extended if the following steps are taken. Exerting too much force at the adjustment stops on either end can result in damage to adjustment mechanism. Dec 23, 2006 got a leaky sporlan b6 solenoid valve was going to replace seat assembly need some clarification on the manual lift stem. Sporlan valve f6solenoid 34 npt r246p1 saez distributors. Mopd ratings of most sporlan solenoid valves allow their use on. Can be used with most commercially available cfc, hcfc and hfc. Evaporator pressure regulating valves soritpi2, 3, 4 and 5 features n piloted internally no high side connection required n superior corrosion resistance n optional solenoid stop feature to close valve during defrost n optional electric open feature for two temperature operation n manual lift stem standard to allow system. If your solenoid valve is extremely hot or emitting smoke immediately disconnect the. This feature will simplify servicing by permitting a vacuum to be pulled through the valve. Let me start out with saying i am new to the cooler freezer refrigerant side.
Once the valve is feeding, monitor the superheat as the system goes through a pulldown. Sporlan b9s2 solenoid valve coil kc2126 120240 v 60 cycle 12 odf x 58 odm capacities. Place the valve in the line in the proper direction of flow and solder. Got a leaky sporlan b6 solenoid valve was going to replace seat assembly need some clarification on the manual lift stem.
Manual lift stem if required the molded mkc1 coil fits the e2, a3, e3, w3, s4, e5, b6, e6, s6, w6, s7, e8, e10s1, e35, e43, r183, r184 and r246 series normally closed solenoid valves. The slots in the bracket match the tapped holes in the standard solenoid valves so that they may be secured by two screws supplied with the bracket. One of the most common is the normallyclosed type, in which the valves opens when the coil is energized, and closes when the coil is deenergized. I took a me10s250 solenoid valve apart to solder it on my liquid line this afternoon i noticed when i pulled the seat disc out, the o ring around it was not a complete ring.
Most sporlan solenoid valves are listed by underwriters laboratories, inc. Sporlan offers thermostatic expansion valves in r410a nominal capacities between. Dec 06, 2000 proceed to adjust the valve by turning the valve stem clockwise to increase superheat until the system is just stable. Use a sporlan strainer for water applications upstream of every industrial solenoid valve. I am more advanced in tracing out a circuit than i am with the refrigerant side. Manual lift stem the manual lift stem is located in the bottom of the main valve body. The asco redhat brand offers the worlds largest selection of 2way, 3way and 4way solenoid valves, designed to handle the most demanding fluid control applications. Parker valve types can be manual, motor actuated or solenoid operated while. The omkc1 coil fits the oe6, oe8, oe10s1, oe35 and oe43 series and the xwg, xup and xxf series rapid cycle solenoid valves.